CVE-2021-25661
7.5 HIGHA vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl
Published: 2021-05-12 · Last updated: 2026-06-02
Severity and scoring
- CVSS
- 7.5 HIGH
- Vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- CWE
- CWE-788
Affected products
| Vendor | Product |
|---|---|
| siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware, simatic_hmi_comfort_outdoor_panels_7\"_firmware, simatic_hmi_comfort_panels_22\"_firmware |
Description
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.
Source: NVD
References
- [NVD]https://nvd.nist.gov/vuln/detail/CVE-2021-25661
- [Vendor advisory]https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
- [Other]https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12
- [Vendor advisory]https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf
- [Other]https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12
Related CVEs
Same vendor
- CVE-2026-46749 — A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6) (7.5 HIGH)
- CVE-2026-46748 — A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6) (8.8 HIGH)
- CVE-2026-46747 — A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6) (4.3 MEDIUM)
- CVE-2026-46746 — A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6) (8.8 HIGH)
- CVE-2026-0257 — Authentication bypass vulnerabilities in the GlobalProtect portal and gateway of Palo Alto Networks PAN-OS® software allows the attacker ... (9.1 CRITICAL)
Same CWE
- CVE-2021-27384 — A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl (9.8 CRITICAL)
- CVE-2021-25660 — A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl (7.5 HIGH)