CVE Watch
Every published CVE, mapped to engagement reality.
Crawled from cve.org every day. Each entry annotated with the QSearch coverage signal — how many of our agents, skills, and playbooks address the technique. Subscribe via RSS for SIEM pipe, or get the weekly digest by email.
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versi...
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
rockwellautomationCWE-287CWE-603Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versi...
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable.
rockwellautomationCWE-327A vulnerability has been identified in SIMATIC S7-300 CPU family (incl
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
siemensCWE-400In all versions of Omron PLC CJ Series, an attacker can send a series of specific data packets within a short period, causing a service e...
In all versions of Omron PLC CJ Series, an attacker can send a series of specific data packets within a short period, causing a service error on the PLC Ethernet module, which in turn causes a PLC service denied result.
omronCWE-400A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modi...
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
schneider-electricCWE-754A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modi...
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
schneider-electricCWE-754A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modi...
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
schneider-electricCWE-754In Omron PLC CJ series, all versions, and Omron PLC CS series, all versions, an attacker could monitor traffic between the PLC and the co...
In Omron PLC CJ series, all versions, and Omron PLC CS series, all versions, an attacker could monitor traffic between the PLC and the controller and replay requests that could result in the opening and closing of industrial valves.
omronCWE-294In the Linux kernel 5.0.21, mounting a crafted btrfs filesystem image can lead to slab-out-of-bounds write access in index_rbio_pages in ...
In the Linux kernel 5.0.21, mounting a crafted btrfs filesystem image can lead to slab-out-of-bounds write access in index_rbio_pages in fs/btrfs/raid56.c.
linuxCWE-787Use after free in PDFium in Google Chrome prior to 78.0.3904.87 allowed a remote attacker to potentially exploit heap corruption via a cr...
Use after free in PDFium in Google Chrome prior to 78.0.3904.87 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.
googleCWE-416CWE-787A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium...
A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.
schneider-electricCWE-200In xsltCopyText in transform.c in libxslt 1.1.33, a pointer variable isn't reset under certain circumstances
In xsltCopyText in transform.c in libxslt 1.1.33, a pointer variable isn't reset under certain circumstances. If the relevant memory area happened to be freed and reused in a certain way, a bounds check could fail and memory outside a buffer could be written to, or uninitialized data could be disclosed.
canonicaldebianxmlsoftCWE-416CWE-908Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited...
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that can reference memory after it has been freed.
redlionCWE-416Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited...
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that causes the program to mishandle pointers.
redlionCWE-465Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited...
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that operates outside of the designated memory area.
redlionCWE-119A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version p...
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus.
schneider-electricCWE-248CWE-755Linaro/OP-TEE OP-TEE 3.3.0 and earlier is affected by: Rounding error
Linaro/OP-TEE OP-TEE 3.3.0 and earlier is affected by: Rounding error. The impact is: Potentially leaking code and/or data from previous Trusted Application. The component is: optee_os. The fixed version is: 3.4.0 and later.
trustedfirmwareCWE-189The Orpak SiteOmat OrCU component is vulnerable to code injection, for all versions prior to 2017-09-25, due to a search query that uses ...
The Orpak SiteOmat OrCU component is vulnerable to code injection, for all versions prior to 2017-09-25, due to a search query that uses a direct shell command. By tampering with the request, an attacker is able to run shell commands and receive valid output from the device.
orpakCWE-94An insecure communication was found between a user and the Orpak SiteOmat management console for all known versions, due to an invalid SS...
An insecure communication was found between a user and the Orpak SiteOmat management console for all known versions, due to an invalid SSL certificate. The attack allows for an eavesdropper to capture the communication and decrypt the data.
orpakCWE-310CWE-311A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration ...
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
schneider-electricCWE-306
Weekly digest
Get the curated CVE digest every Monday
One email a week, sent Monday morning CET. The CVEs published or modified in the last seven days, severity-ordered, with the QSearch coverage signal. Unsubscribe with one click — included in every send.
Pipe the CVE feed into your stack.