QSearchQSearch
A vertical stack of five horizontal severity-tier bars rendered with Swiss tabular precision, descending in opacity from a hot volt-lime upper bar through a cooler signal-blue lower bar, evoking vulnerability severity stratification

CVE Watch

Every published CVE, mapped to engagement reality.

Crawled from cve.org every day. Each entry annotated with the QSearch coverage signal — how many of our agents, skills, and playbooks address the technique. Subscribe via RSS for SIEM pipe, or get the weekly digest by email.

Tracking 10103 CVEsUpdated dailyLatest entry 2026-06-16
  • CVE-2026-94018.8 HIGH2026-05-24

    A vulnerability has been found in Edimax BR-6675nD 1.12

    A vulnerability has been found in Edimax BR-6675nD 1.12. Impacted is the function formWanTcpipSetup of the file /goform/formWanTcpipSetup of the component POST Request Handler. The manipulation of the argument pppUserName leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

    CWE-119CWE-120
  • CVE-2026-94006.3 MEDIUM2026-05-24

    A flaw has been found in Edimax BR-6675nD 1.12

    A flaw has been found in Edimax BR-6675nD 1.12. This issue affects the function formUSBStorage of the file /goform/formUSBStorage of the component POST Request Handler. Executing a manipulation of the argument sub_dir can lead to command injection. It is possible to launch the attack remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

    CWE-74CWE-77
  • CVE-2026-488323.5 LOW2026-05-24

    action/cookie.php in ecrire in SPIP before 4.4.15 is prone to an open redirect vulnerability

    action/cookie.php in ecrire in SPIP before 4.4.15 is prone to an open redirect vulnerability.

    CWE-601
  • CVE-2026-93998.8 HIGH2026-05-24

    A vulnerability was detected in Edimax BR-6675nD 1.12

    A vulnerability was detected in Edimax BR-6675nD 1.12. This vulnerability affects the function formsetPPPoE of the file /goform/formsetPPPoE of the component POST Request Handler. Performing a manipulation of the argument pppUserName results in buffer overflow. It is possible to initiate the attack remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

    CWE-119CWE-120
  • CVE-2026-93983.1 LOW2026-05-24

    A security vulnerability has been detected in Besen BS20 EV Charging Station up to 20260426

    A security vulnerability has been detected in Besen BS20 EV Charging Station up to 20260426. This affects an unknown part of the component BLE/WiFi. Such manipulation leads to authentication bypass by capture-replay. The attack must be carried out from within the local network. Attacks of this nature are highly complex. It is indicated that the exploitability is difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."

    CWE-287CWE-294
  • CVE-2026-93978.1 HIGH2026-05-24

    A weakness has been identified in Besen BS20 EV Charging Station up to 20260426

    A weakness has been identified in Besen BS20 EV Charging Station up to 20260426. Affected by this issue is some unknown functionality of the component OTA Update Installation Handler. This manipulation causes improper authorization. The attack is possible to be carried out remotely. A high degree of complexity is needed for the attack. The exploitation is known to be difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."

    CWE-266CWE-285
  • CVE-2026-93963.7 LOW2026-05-24

    A security flaw has been discovered in Besen BS20 EV Charging Station up to 20260426

    A security flaw has been discovered in Besen BS20 EV Charging Station up to 20260426. Affected by this vulnerability is an unknown functionality of the component Firmware Version Check. The manipulation results in improper restriction of rendered ui layers. The attack can be executed remotely. A high complexity level is associated with this attack. The exploitation appears to be difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."

    CWE-1021
  • CVE-2026-93953.5 LOW2026-05-24

    A vulnerability was identified in Besen BS20 EV Charging Station up to 20260426

    A vulnerability was identified in Besen BS20 EV Charging Station up to 20260426. Affected is an unknown function of the component BLE/UDP. The manipulation leads to insufficiently protected credentials. The attack needs to be initiated within the local network. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."

    CWE-522
  • CVE-2026-93943.1 LOW2026-05-24

    A vulnerability was determined in Besen BS20 EV Charging Station up to 20260426

    A vulnerability was determined in Besen BS20 EV Charging Station up to 20260426. This impacts an unknown function of the component Bluetooth Low Energy Handler. Executing a manipulation can lead to weak password requirements. The attack needs to be done within the local network. This attack is characterized by high complexity. The exploitability is said to be difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."

    CWE-521
  • CVE-2026-93938.8 HIGH2026-05-24

    A vulnerability was found in H3C Magic B0 up to 100R002

    A vulnerability was found in H3C Magic B0 up to 100R002. This affects the function Edit_BasicSSID_5G of the file /goform/aspForm. Performing a manipulation of the argument param results in buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

    CWE-119CWE-120
  • CVE-2026-93898.8 HIGH2026-05-24

    A security vulnerability has been detected in Tenda F456 1.0.0.5

    A security vulnerability has been detected in Tenda F456 1.0.0.5. This affects the function frmL7ImForm of the file /goform/L7Im. The manipulation of the argument page leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

    CWE-119CWE-120
  • CVE-2026-93837.3 HIGH2026-05-24

    A vulnerability has been found in itsourcecode Electronic Judging System 1.0

    A vulnerability has been found in itsourcecode Electronic Judging System 1.0. This affects an unknown part of the file /intrams/admin/login.php. The manipulation of the argument Username leads to sql injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.

    CWE-74CWE-89
  • CVE-2026-43727.8 HIGH2026-05-24

    A critical remote code execution vulnerability exists in all versions of the HuggingFace transformers library prior to version 5.3.0

    A critical remote code execution vulnerability exists in all versions of the HuggingFace transformers library prior to version 5.3.0. The vulnerability allows an attacker to craft a malicious `config.json` file containing the `_attn_implementation_internal` field set to an attacker-controlled HuggingFace Hub repository ID. When a victim loads this model using the standard `AutoModelForCausalLM.from_pretrained()` API, the library downloads and executes arbitrary Python code from the attacker's repository with the victim's full OS privileges. This issue arises due to unfiltered deserialization of configuration attributes, insufficient sanitization of internal fields, and unsandboxed execution of downloaded kernels. The vulnerability bypasses the `trust_remote_code` security mechanism, is invisible to the victim, and exploits the standard documented usage pattern, making it particularly severe. Users are advised to upgrade to version 5.3.0 or later to mitigate this issue.

    huggingfaceCWE-1066CWE-502
  • CVE-2026-93828.8 HIGH2026-05-24

    A flaw has been found in Edimax BR-6675nD 1.12

    A flaw has been found in Edimax BR-6675nD 1.12. Affected by this issue is the function formPPTPSetup of the file /goform/formPPTPSetup of the component POST Request Handler. Executing a manipulation of the argument pptpUserName can lead to buffer overflow. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

    CWE-119CWE-120
  • CVE-2026-93818.8 HIGH2026-05-24

    A vulnerability was detected in Edimax BR-6675nD 1.12

    A vulnerability was detected in Edimax BR-6675nD 1.12. Affected by this vulnerability is the function formPPPoESetup of the file /goform/formPPPoESetup of the component POST Request Handler. Performing a manipulation of the argument pppUserName results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

    CWE-119CWE-120
  • CVE-2026-93808.8 HIGH2026-05-24

    A security vulnerability has been detected in Edimax BR-6675nD 1.12

    A security vulnerability has been detected in Edimax BR-6675nD 1.12. Affected is the function formL2TPSetup of the file /goform/formL2TPSetup of the component POST Request Handler. Such manipulation of the argument L2TPUserName leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

    CWE-119CWE-120
  • CVE-2026-93796.3 MEDIUM2026-05-24

    A weakness has been identified in Edimax BR-6675nD 1.12

    A weakness has been identified in Edimax BR-6675nD 1.12. This impacts the function formWpsStart of the file /goform/formWpsStart of the component POST Request Handler. This manipulation of the argument pinCode causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

    CWE-74CWE-77
  • CVE-2026-93786.3 MEDIUM2026-05-24

    A security flaw has been discovered in Edimax BR-6675nD 1.12

    A security flaw has been discovered in Edimax BR-6675nD 1.12. This affects the function formHwSet of the file /goform/formHwSet of the component POST Request Handler. The manipulation of the argument regDomain/ABandregDomain/nic0Addr/nic1Addr/wlanAddr/inicAddr results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

    CWE-74CWE-77
  • CVE-2026-93772.4 LOW2026-05-24

    A vulnerability was identified in SourceCodester SUP Online Shopping 1.0

    A vulnerability was identified in SourceCodester SUP Online Shopping 1.0. The impacted element is an unknown function of the file /admin/productedit.php. The manipulation of the argument productName leads to cross site scripting. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.

    CWE-79CWE-94
  • CVE-2026-93766.3 MEDIUM2026-05-24

    A vulnerability was determined in JPress up to 1.0.3

    A vulnerability was determined in JPress up to 1.0.3. The affected element is an unknown function of the file /ucenter/article/doWriteSave of the component UCenter Article Submission Endpoint. Executing a manipulation of the argument id/userId can lead to improper authorization. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The project was informed of the problem early through an issue report but has not responded yet.

    CWE-266CWE-285

Weekly digest

Get the curated CVE digest every Monday

One email a week, sent Monday morning CET. The CVEs published or modified in the last seven days, severity-ordered, with the QSearch coverage signal. Unsubscribe with one click — included in every send.

Pipe the CVE feed into your stack.

CVE Watch publishes RSS, Atom, and JSON feeds — wire them into your SIEM, Slack, Discord, or your RSS reader of choice. Or get the curated weekly digest by email.