CVE Watch
Every published CVE, mapped to engagement reality.
Crawled from cve.org every day. Each entry annotated with the QSearch coverage signal — how many of our agents, skills, and playbooks address the technique. Subscribe via RSS for SIEM pipe, or get the weekly digest by email.
app/Model/Attribute.php in MISP 2.4.127 lacks an ACL lookup on attribute correlations
app/Model/Attribute.php in MISP 2.4.127 lacks an ACL lookup on attribute correlations. This occurs when querying the attribute restsearch API, revealing metadata about a correlating but unreachable attribute.
misp-projectCWE-862An issue was discovered in the jsrsasign package before 8.0.17 for Node.js
An issue was discovered in the jsrsasign package before 8.0.17 for Node.js. Its RSASSA-PSS (RSA-PSS) implementation does not detect signature manipulation/modification by prepending '\0' bytes to a signature (it accepts these modified signatures as valid). An attacker can abuse this behavior in an application by creating multiple valid signatures where only one signature should exist. Also, an attacker might prepend these bytes with the goal of triggering memory corruption issues.
kjurnetappCWE-119An issue was discovered in the jsrsasign package before 8.0.18 for Node.js
An issue was discovered in the jsrsasign package before 8.0.18 for Node.js. Its RSA PKCS1 v1.5 decryption implementation does not detect ciphertext modification by prepending '\0' bytes to ciphertexts (it decrypts modified ciphertexts without error). An attacker might prepend these bytes with the goal of triggering memory corruption issues.
kjurnetappCWE-119An issue was discovered in the jsrsasign package through 8.0.18 for Node.js
An issue was discovered in the jsrsasign package through 8.0.18 for Node.js. It allows a malleability in ECDSA signatures by not checking overflows in the length of a sequence and '0' characters appended or prepended to an integer. The modified signatures are verified as valid. This could have a security-relevant impact if an application relied on a single canonical signature.
kjurnetappCWE-347Improper validation of certificate with host mismatch in Apache Log4j SMTP appender
Improper validation of certificate with host mismatch in Apache Log4j SMTP appender. This could allow an SMTPS connection to be intercepted by a man-in-the-middle attack which could leak any log messages sent through that appender. Fixed in Apache Log4j 2.12.3 and 2.13.1
apachedebianoracleCWE-295A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoS...
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller.
schneider-electricCWE-74A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted betwee...
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.
schneider-electricCWE-319snd_ctl_elem_add in sound/core/control.c in the Linux kernel through 5.6.3 has a count=info->owner line, which later affects a private_si...
snd_ctl_elem_add in sound/core/control.c in the Linux kernel through 5.6.3 has a count=info->owner line, which later affects a private_size*count multiplication for unspecified "interesting side effects." NOTE: kernel engineers dispute this finding, because it could be relevant only if new callers were added that were unfamiliar with the misuse of the info->owner field to represent data unrelated to the "owner" concept. The existing callers, SNDRV_CTL_IOCTL_ELEM_ADD and SNDRV_CTL_IOCTL_ELEM_REPLACE, have been designed to misuse the info->owner field in a safe way
linuxCWE-704A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Vers...
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet – 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus.
schneider-electricCWE-754Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versi...
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller.
rockwellautomationCWE-321CWE-798Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versi...
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
rockwellautomationCWE-287CWE-603Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versi...
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable.
rockwellautomationCWE-327A vulnerability has been identified in SIMATIC S7-300 CPU family (incl
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
siemensCWE-400In all versions of Omron PLC CJ Series, an attacker can send a series of specific data packets within a short period, causing a service e...
In all versions of Omron PLC CJ Series, an attacker can send a series of specific data packets within a short period, causing a service error on the PLC Ethernet module, which in turn causes a PLC service denied result.
omronCWE-400An issue was discovered in MISP before 2.4.121
An issue was discovered in MISP before 2.4.121. The Galaxy view contained an incorrectly sanitized search string in app/View/Galaxies/view.ctp.
misp-projectAn issue was discovered in MISP before 2.4.121
An issue was discovered in MISP before 2.4.121. It did not consider the HTTP PUT method when trying to block a brute-force series of invalid requests.
misp-projectA CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modi...
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
schneider-electricCWE-754A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modi...
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
schneider-electricCWE-754A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modi...
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.
schneider-electricCWE-754Included in Log4j 1.2 is a SocketServer class that is vulnerable to deserialization of untrusted data which can be exploited to remotely ...
Included in Log4j 1.2 is a SocketServer class that is vulnerable to deserialization of untrusted data which can be exploited to remotely execute arbitrary code when combined with a deserialization gadget when listening to untrusted network traffic for log data. This affects Log4j versions up to 1.2 up to 1.2.17.
apachecanonicaldebianCWE-502
Weekly digest
Get the curated CVE digest every Monday
One email a week, sent Monday morning CET. The CVEs published or modified in the last seven days, severity-ordered, with the QSearch coverage signal. Unsubscribe with one click — included in every send.
Pipe the CVE feed into your stack.
CVE Watch publishes RSS, Atom, and JSON feeds — wire them into your SIEM, Slack, Discord, or your RSS reader of choice. Or get the curated weekly digest by email.