
CVE Watch
Every published CVE, mapped to engagement reality.
Crawled from cve.org every day. Each entry annotated with the QSearch coverage signal — how many of our agents, skills, and playbooks address the technique. Subscribe via RSS for SIEM pipe, or get the weekly digest by email.
sqclass.cpp in Squirrel through 2.2.5 and 3.x through 3.1 allows an out-of-bounds read (in the core interpreter) that can lead to Code Ex...
sqclass.cpp in Squirrel through 2.2.5 and 3.x through 3.1 allows an out-of-bounds read (in the core interpreter) that can lead to Code Execution. If a victim executes an attacker-controlled squirrel script, it is possible for the attacker to break out of the squirrel script sandbox even if all dangerous functionality such as File System functions has been disabled. An attacker might abuse this bug to target (for example) Cloud services that allow customization via SquirrelScripts, or distribute malware through video games that embed a Squirrel Engine.
fedoraprojectsquirrel-langCWE-125An issue was discovered in Mbed TLS before 2.28.1 and 3.x before 3.2.0
An issue was discovered in Mbed TLS before 2.28.1 and 3.x before 3.2.0. In some configurations, an unauthenticated attacker can send an invalid ClientHello message to a DTLS server that causes a heap-based buffer over-read of up to 255 bytes. This can cause a server crash or possibly information disclosure based on error responses. Affected configurations have MBEDTLS_SSL_DTLS_CLIENT_PORT_REUSE enabled and MBEDTLS_SSL_IN_CONTENT_LEN less than a threshold that depends on the configuration: 258 bytes if using mbedtls_ssl_cookie_check, and possibly up to 571 bytes with a custom cookie check function.
armdebiantrustedfirmwareCWE-125A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a...
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
schneider-electricCWE-287CWE-345Use of Hard-coded Cryptographic Key in Go github.com/gravitl/netmaker prior to 0.8.5,0.9.4,0.10.0,0.10.1
Use of Hard-coded Cryptographic Key in Go github.com/gravitl/netmaker prior to 0.8.5,0.9.4,0.10.0,0.10.1.
netmakerCWE-321By design, the JDBCAppender in Log4j 1.2.x accepts an SQL statement as a configuration parameter where the values to be inserted are conv...
By design, the JDBCAppender in Log4j 1.2.x accepts an SQL statement as a configuration parameter where the values to be inserted are converters from PatternLayout. The message converter, %m, is likely to always be included. This allows attackers to manipulate the SQL by entering crafted strings into input fields or headers of an application that are logged allowing unintended SQL queries to be executed. Note this issue only affects Log4j 1.x when specifically configured to use the JDBCAppender, which is not the default. Beginning in version 2.0-beta8, the JDBCAppender was re-introduced with proper support for parameterized SQL queries and further customization over the columns written to in logs. Apache Log4j 1.2 reached end of life in August 2015. Users should upgrade to Log4j 2 as it addresses numerous other issues from the previous versions.
apachebroadcomnetappCWE-89Mbed TLS before 3.0.1 has a double free in certain out-of-memory conditions, as demonstrated by an mbedtls_ssl_set_session() failure
Mbed TLS before 3.0.1 has a double free in certain out-of-memory conditions, as demonstrated by an mbedtls_ssl_set_session() failure.
armdebiantrustedfirmwareCWE-415On 2.1.15 version and below of Lider module in LiderAhenk software is leaking it's configurations via an unsecured API
On 2.1.15 version and below of Lider module in LiderAhenk software is leaking it's configurations via an unsecured API. An attacker with an access to the configurations API could get valid LDAP credentials.
pardusCWE-306In Linaro OP-TEE before 3.7.0, by using inconsistent or malformed data, it is possible to call update and final cryptographic functions d...
In Linaro OP-TEE before 3.7.0, by using inconsistent or malformed data, it is possible to call update and final cryptographic functions directly, causing a crash that could leak sensitive information.
trustedfirmwareCWE-327CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow
CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.
codesysCWE-122CWE-787Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all vers...
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
schneider-electricCWE-290A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versi...
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767
schneider-electricCWE-20A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versi...
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276
schneider-electricCWE-20A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versi...
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet
schneider-electricCWE-20A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLog...
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device.
schneider-electricCWE-640A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515...
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
siemensCWE-119A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
siemensCWE-788A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
siemensCWE-306The default configuration of Crimson 3.1 (Build versions prior to 3119.001) allows a user to be able to read and modify the database with...
The default configuration of Crimson 3.1 (Build versions prior to 3119.001) allows a user to be able to read and modify the database without authentication.
redlionCWE-306Prototype pollution vulnerability in 'deephas' versions 1.0.0 through 1.0.5 allows attacker to cause a denial of service and may lead to ...
Prototype pollution vulnerability in 'deephas' versions 1.0.0 through 1.0.5 allows attacker to cause a denial of service and may lead to remote code execution.
sharpredCWE-1321A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
siemensCWE-307
Weekly digest
Get the curated CVE digest every Monday
One email a week, sent Monday morning CET. The CVEs published or modified in the last seven days, severity-ordered, with the QSearch coverage signal. Unsubscribe with one click — included in every send.
Pipe the CVE feed into your stack.
CVE Watch publishes RSS, Atom, and JSON feeds — wire them into your SIEM, Slack, Discord, or your RSS reader of choice. Or get the curated weekly digest by email.